What is the difference between RW90 and RWU90?

Aluminum RWU90 is a cross linked polyethylene insulated single conductor The insulation is thicker than that of the RW90 making it suitable for direct earth burial. The available size range is from #8 AWG to 750 kcmil. Applications include service entrance below ground. RWU90 can only be specified as 1000 Volts.

Can RW90 be used underground?

With a rating of 600 volts, NUAL Brand RW90 can be installed in enclosed raceways in both wet and dry locations and are designed for use as service, feeder or branch circuits. Standard RW90 may be pulled into underground ducts, but is not approved for direct burial in earth.

What does RW90 cable stand for?

Moisture resistant 60°C. RW90: Canadian Standards Association (CSA) designation for a wire or cable with rubber or rubber like insulation suitable for use in wet or dry locations at a maximum temperature of 90°C.

What does ACWU cable stand for?

Armoured Cable Wet Underground
ACWU, which stands for Armoured Cable Wet Underground, is an armoured cable used for exposed and concealed wiring in wet or dry locations. It is typically constructed with 1 to 4 conductors, wrapped in an aluminum interlocking armour exterior.

Does RW90 need to be in conduit?

CSA listed RW90 type stranded copper wire. This wire is rated for use in dry or wet locations, raceways, or conduit. It can be used outside exposed to the weather as well, though the insulation is not 100% UV-proof and installation in conduit is recommended.

Is RW90 wet rated?

Single copper conductor with low temperature moisture resisting Exelene* cross-linked polyethylene insulation. For open wiring and raceways (except cable troughs and ventilated flexible cableway) in dry or wet locations.

What is the maximum spacing between supports for 1 conduit?

Supports for Rigid Metallic Conduit

Conduit Size Distance Between Supports
1″ 12 Feet
1¼” – 1½” 14 Feet
2″ – 2½” 16 Feet
3″ and larger 20 Feet

How deep does Hydro need to be buried?

The generally applicable depth is 12 inches, or you can reduce it to 6 inches if you protect the cables with 2 inches of concrete. Under a driveway, you may only need 12 inches of burial depth. Conduits are required for installation in 2 inches of solid rock with concrete.

What does TW stand for in wires?

TW or THW means thermoplastic high heat-resistant and water-resistant. Typical uses of TW/THW electrical wire tracer are in control panels, air conditioning equipment, refrigeration equipment, control wiring of machine tools, and automatic washers.

What is T90 wire?

T90 cables are primarily used for power distribution. They may be used in wet or dry locations, with. conductor temperatures not exceeding 90°C for dry locations. Voltage rating for T90 cable is 600V. Conductors: Stranded soft drawn bare copper, with Class B stranding per ASTM.

Is ACWU always aluminum?

ACWU is acceptable for use in wet and underground locations as per the Canadian Electrical Code. Cables are manufactured with one two, three, or four 8000 series aluminum ACM conductors insulated with RW90 cross-linked polyethylene rated at 600 volts from #8 AWG to 750 MCM. The bonding conductor is bare aluminum.

What does AC 90 stand for?

Copper Conductor
Copper Conductor AC90 is a flexible interlocked aluminum armoured cable approved for use in open and concealed wiring in dry locations. All AC90 is CSA approved and manufactured with two, three, or four copper conductors insulated with RW90 cross-linked polyethylene rated at 600 volts from #14 to #2 AWG.